>

Baumer Space restrictions, vibrations, dirt - optimum for Baumer magnetic sensors



Baumer Space restrictions, vibrations, dirt - optimum for Baumer magnetic sensors


. Simple assembly
. Suitable for large shaft diameters
. Bearingless operation
. Compact designs
. Flexible combinations of sensor and magnet

Baumer Special sensors for angular measurement




. Inclinometers
. Speed switches
. Resolvers
. Combinations
. Cable pull assembly
. Encoders with SIL certification
. Encoders for EX applications
. Robust stainless steel variants

Baumer Tachogenerators - precise and durable



Baumer Tachogenerators - precise and durable

. Highest transformation accuracy over the entire speed range
. Outstanding, maintenance-free service lives
. Broad range of designs

Baumer Magnetic sensors - robust and modular


Baumer Magnetic sensors - robust and modular

. For linear or rotational movements
. Wear-free measurement
. Incremental versions with rectangular- or sine-wave signal output
. Absolute versions with analog, SSI, fieldbus or Ethernet interfaces

Baumer Absolute encoders - innovative and flexible




. All common interfaces
. Touchless Multiturn or Multiturn
Generator . Magnetic or optical sensing
. Miniature, kit and HeavyDuty versions

Baumer Incremental encoders - manifold and precise




. From miniature to HeavyDuty versions
. Hollow shaft and shaft versions
. Magnetic or optical sensing
. Rectangular- or sine-wave signals

Baumer Strain sensors




. Static and dynamic applications
. Accuracy < 1 %
. Measuring range +/-100 . +/-750 µe
. Transducer, CANopen, voltage or current output
. Protection class IP 65


Baumer Force sensors




. Static and dynamic applications
. Accuracy 0,3 %
. Sensibility 2 mV/V
. Force range 500 N to 100 kN
. Tension / compression applications
. Protection class IP 67

Baumer My-Com precision switches ±1 µm





. ±1 µm repeat accuracy
. Activating pin made of unbreakable zirconium oxide
. 30 cN minimum activating force
. Pointed activating pins
. 2-wire normally closed contact (NC) and 3-wire normally open contact (NO)
. Lateral approach also possible to 30° (spherical activating pins)
. Also in protection class IP 67

Baumer Magnetic sensors




. Non-wearing systems
. For rotating and linear applications
. Tolerant of dust and dirt
. Two-channel and three-channel version with zero pulse
. High resolution
. Absolute position measurement up to 360° of rotation
. Protection class IP 67
. Scanning of gears and racks starting with module 1

Baumer Ultrasonic sensors



. Sensing range to 3000 mm
. Reliable detection of highly reflective and transparent objects
. Tolerant of dust and dirt
. Versions with two separate switching outputs
. Also for sensing sound-absorbing materials
. Adjustable reaction times ton/toff for through beam sensors
. Protection class IP 67
. Output PNP/NPN

Baumer Distance measuring ultrasonic sensors




. Measuring range to 2500 mm
. Individual measuring range adjustable
. Reliable sensing of highly reflective and transparent surfaces
. Tolerant of dust and dirt
. Suitable for level measurement of liquids, granulates and pastes
. Narrow and wide sonic beam angles
. Protection class IP 67

Baumer Vision sensors VeriSens




. Simple object detection using several features with one compact sensor
. Flexible applications due to extensive function library from brightness sensor to contour sensor
. Powerful, contour-based position correction for fast object detection
. Focus adjustment for different working distance
. Reliable operation even under fluctuating light conditions due to latest contour-based image processor technology
. Quick setup using intuitive user guidance and pre-configured sensor functions

Baumer Line sensors ParCon and PosCon




. High resolution to 0,03 mm
. Measuring frequency to 1 kHz
. Measuring range of 24 mm to 875 mm
. Robust metal housing
. Simple operation at the sensor
. Integrated evaluation electronics
. Measuring or digital version

Baumer Laser copy counters SCATEC




. Counting rate up to 3 million copies / h
. Large operating range 0 . 120 mm
. Detects single sheets to 0,1 mm
. False pulse suppression
. Trailing edge suppression and direct gap detection
. Synchronized input
. Diagnostic software available
. Output push-pull

Baumer Photoelectric level monitoring and leak detecting sensors




. Liquid level sensors up to 40 bar nominal pressure
. Liquid level sensors for installation on risers
. Chemically resistant
. Sensors to monitor for leaks
. Fiber optic version
. Output PNP/NPN

Baumer Fiber optics sensors



. Plastic and glass fiber optics
. Extremely varied fiber optic heads
. Very compact housings
. Sensitivity adjustment with Teach-in or potentiometer
. Quick response times to 0,05 ms
. Adjustable on / off delay
. Master-Slave systems (minimized wiring expense)
. Output PNP/NPN, analog

Baumer Color sensors LOGIPAL / Measuring light barriers SpiderScan




. 4 color channels
. Adjustable color tolerance
. Quick response time 0,34 ms
. Different spot sizes
. Output PNP/NPN
. Very high measuring frequency 100 kHz
. Measuring range to 1,67 m
. Resolution 2,5 mm
. Robust metal housing, IP 65

Baumer Photoelectric Fork sensors



. Quick response times to 0,01 ms
. High repeat accuracy
. Robust metal housing
. Narrow parallel light beam
. Smallest detectable object 0,05 mm
. Different gap widths 3 . 158 mm
. Output PNP/NPN

Baumer Photoelectric sensors





. Precise background suppression
. Retro-reflective sensor with polarization filter
. Response time to 50 µs
. Sensing distance to 20 m
. Laser beams with diameters to 1,0 mm
. Extremely small housings
. Sensors in robust metal housing
. Sensors for transparent objects
. Output PNP/NPN, push-pull

Baumer Distance measuring photoelectric sensors




. Precise distance measuring
. Virtually independent of the object condition
. Highest resolution to 2 µm
. Suitable for high-speed processes
. Measuring range can be individually set using Teach-in
. Extremely compact housing
. Completely integrated evaluation electronics
. High temperature stability
. High ambient light immunity
. Protection class IP 67

Baumer Capacitive Sensors



. Various housings
. Expanded temperature ranges
. Active area made of Teflon
. Detects the most varied materials
. No blind region
. Detection possible even through container wall
. Reduced susceptibility to contamination using compensation electrode
. Protection class IP 67
. Output PNP/NPN

Baumer Inductive sensors with full metal housing DuroProx



. Housing of stainless steel 1.4404 (V4A)
. Compact and extremely robust versions
. Protection class IP 69K
. Expanded temperature ranges
. Output PNP/NPN
. High switching point accuracy
. Small series variance
. High switching frequency
. Wide product range
. Output PNP/NPN


Baumer Inductive sensors, cylindrical type


Baumer Inductive sensors, cylindrical type

. Smallest series variance
. Extremely termperature-stable
. High switching frequency
. Enhanced distance
. Miniature sensors
. Several housing lengths per dimension
. Expanded temperature ranges
. Protection class IP 67
. Output PNP/NPN


Baumer Distance Measuring Inductive Sensors




. High Resolution up to 0, 1 um
. Absolute Distance Measuring up to 16mm
. High repeat Accuracy
. Quick Response time up to 0, 5 ms
. Low Temperature drift
. Linearized output signals
. External Signal Processing unnecssary
. With Teach- in functions